Loading dataset
Data viewTableSummary
Data viewTableSummary
Updated

8.8 MB across 1 part, newest sealed 8 November 2026 at 09:39 UTC. The first build wrote 1 part and 116,443 rows.

All 8 checks passed.
  • Facility id unique passed.
  • Facility id present passed.
  • Operator present passed.
  • Nonempty register passed.
  • Valid latitude passed.
  • Valid longitude passed.
  • Clef model present passed.
  • Clef sector present passed.

facility_id

string

Official registry identifier of this charging facility.

  • 10000000%
  • 10000010%
  • 10000020%
  • Other (116,431)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
116,443 · 100% of valid

operator

string

Operator name as published, with outer whitespace removed.

  • EnBW mobility+ AG und Co.KG5%
  • Tesla Germany GmbH3%
  • E.ON Drive Germany GmbH3%
  • Other (11,737)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
11,749 · 10.1% of valid

display_name

string

Name displayed on the agency map.

  • E.ON Drive GmbH6%
  • EWE Go GmbH3%
  • Wirelane GmbH3%
  • Other (1,908)
Valid
51,865 · 44.5%
Missing
64,578 · 55.5%
Missing over timeMissing share of display_name over time, 0% to 100%.
Distinct
1,920 · 3.7% of valid

status

string

Reported operational status.

  • In Betrieb100%
  • In Wartung0%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2 · 0% of valid

facility_type

string

Reported normal or rapid charging facility category.

  • Normalladeeinrichtung73%
  • Schnellladeeinrichtung27%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2 · 0% of valid

charge_point_count

integer

Number of charging points belonging to the facility.

Histogram: 1 to 1.8333333333333335, 32,333; 1.8333333333333335 to 2.666666666666667, 78,762; 2.666666666666667 to 3.5, 2,389; 3.5 to 4.333333333333334, 2,808; 4.333333333333334 to 5.166666666666667, 26; 5.166666666666667 to 6, 125
16
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
6 · 0% of valid
Min
1
25%
1
Median
2
75%
2
Max
6

facility_power_kw

decimal

Rated power of the facility in kilowatts.

  • 22.00000029%
  • 44.00000025%
  • 11.00000012%
  • Other (241)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
253 · 0.2% of valid
Min
1.000000
25%
22.000000
Median
44.000000
75%
50.000000
Max
1800.000000

commissioned_on

date

Commissioning date reported by the operator.

  • 2023-03-201%
  • 2022-01-011%
  • 2024-01-011%
  • Other (3,912)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
3,924 · 3.4% of valid

street

string

Street of the facility address.

  • Bahnhofstr.1%
  • Hauptstr.1%
  • Hauptstraße1%
  • Other (34,591)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
34,603 · 29.7% of valid

house_number

string

House number, retained as text.

  • 111%
  • 07%
  • 26%
  • Other (2,618)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2,630 · 2.3% of valid

address_extra

string

Additional address information.

  • Parkplatz6%
  • Parkhaus3%
  • Tiefgarage3%
  • Other (8,513)
Valid
20,659 · 17.7%
Missing
95,784 · 82.3%
Missing over timeMissing share of address_extra over time, 0% to 100%.
Distinct
8,525 · 41.3% of valid

postal_code

string

Postal code, retained as text to preserve leading zeros.

  • 155371%
  • 809370%
  • 654280%
  • Other (7,303)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
7,315 · 6.3% of valid

city

string

Municipality of the facility.

  • Berlin4%
  • Hamburg3%
  • Stuttgart2%
  • Other (7,675)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
7,687 · 6.6% of valid

district

string

Administrative district or independent city.

  • Kreisfreie Stadt Berlin4%
  • Kreisfreie Stadt Hamburg3%
  • Stadtkreis Stuttgart2%
  • Other (389)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
401 · 0.3% of valid

state

string

German federal state.

  • Bayern20%
  • Nordrhein-Westfalen19%
  • Baden-Württemberg16%
  • Other (4)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
16 · 0% of valid

latitude

decimal

Published latitude in decimal degrees.

  • 52.3913310%
  • 50.0797700%
  • 54.3245900%
  • Other (73,237)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
73,249 · 62.9% of valid
Min
47.352641
25%
48.999043
Median
50.815900
75%
52.190434
Max
55.122778

longitude

decimal

Published longitude in decimal degrees.

  • 13.7921500%
  • 8.2206200%
  • 7.3640500%
  • Other (73,609)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
73,621 · 63.2% of valid
Min
4.000000
25%
8.160770
Median
9.474400
75%
11.326855
Max
15.000000

location_name

string

Operator supplied location label.

  • Parkhaus Elsässer Platz1%
  • P440%
  • Parkplatz0%
  • Other (21,808)
Valid
32,529 · 27.9%
Missing
83,914 · 72.1%
Missing over timeMissing share of location_name over time, 0% to 100%.
Distinct
21,820 · 67.1% of valid

parking_info

string

Parking restrictions or other parking information.

  • Keine Beschränkung88%
  • Nur für Kunden/Besucher12%
  • keine Beschränkung0%
Valid
58,134 · 49.9%
Missing
58,309 · 50.1%
Missing over timeMissing share of parking_info over time, 0% to 100%.
Distinct
5 · 0% of valid

payment_methods

string

Published payment methods; semicolon lists retained.

  • Onlinezahlungsverfahren;RFID-Karte33%
  • Onlinezahlungsverfahren;RFID-Karte;Sonstige9%
  • RFID-Karte;Onlinezahlungsverfahren7%
  • Other (1,389)
Valid
104,434 · 89.7%
Missing
12,009 · 10.3%
Missing over timeMissing share of payment_methods over time, 0% to 100%.
Distinct
1,401 · 1.3% of valid

opening_hours

string

Published opening hours category.

  • Keine Angabe64%
  • 24735%
  • Eingeschränkt2%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
3 · 0% of valid

opening_weekdays

string

Published opening weekdays; lists retained.

  • Montag; Dienstag; Mittwoch; Donnerstag; Freitag; Samstag; Sonntag97%
  • Montag; Dienstag; Mittwoch; Donnerstag; Freitag; Samstag2%
  • Montag; Dienstag; Mittwoch; Donnerstag; Freitag1%
  • Other (17)
Valid
42,112 · 36.2%
Missing
74,331 · 63.8%
Missing over timeMissing share of opening_weekdays over time, 0% to 100%.
Distinct
29 · 0.1% of valid

opening_times

string

Published opening time intervals; lists retained.

  • 00:00-23:59; 00:00-23:59; 00:00-23:59; 00:00-23:59; 00:00-23:59; 00:00-23:59; 00:00-23:5996%
  • 06:00-22:00; 06:00-22:00; 06:00-22:00; 06:00-22:00; 06:00-22:00; 06:00-22:00; 06:00-22:000%
  • 08:00-12:00; 08:00-12:00; 08:00-12:00; 08:00-12:00; 08:00-12:000%
  • Other (414)
Valid
42,112 · 36.2%
Missing
74,331 · 63.8%
Missing over timeMissing share of opening_times over time, 0% to 100%.
Distinct
426 · 1% of valid

connector_types_1

string

Published connector types for charging point slot 1.

  • AC Typ 2 Steckdose61%
  • DC Fahrzeugkupplung Typ Combo 2 (CCS)25%
  • AC Typ 2 Fahrzeugkupplung9%
  • Other (46)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
58 · 0% of valid

connector_power_kw_text_1

string

Published connector power values in kilowatts, retained as text because multiple connectors may be listed for charging point slot 1.

  • 2249%
  • 1119%
  • 3005%
  • Other (284)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
296 · 0.3% of valid

evse_id_1

string

Published EVSE identifier for charging point slot 1.

  • DEBGL0%
  • DEBRP0%
  • DE BGL0%
  • Other (36,759)
Valid
37,316 · 32%
Missing
79,127 · 68%
Missing over timeMissing share of evse_id_1 over time, 0% to 100%.
Distinct
36,771 · 98.5% of valid

public_key_1

string

Published meter verification public key for charging point slot 1.

  • Wird nachgereicht0%
  • SAM0%
  • 3059301306072a8648ce3d020106082a8648ce3d0301070342000430d17c08f733be1f69f0631efa5872b728b35f30a3c5911d89c751b89668d908440dc4362949ee3532b93078709eb7539e59cd56ce0706b1748b757038f2e1da0%
  • Other (33,741)
Valid
34,844 · 29.9%
Missing
81,599 · 70.1%
Missing over timeMissing share of public_key_1 over time, 0% to 100%.
Distinct
33,753 · 96.9% of valid

connector_types_2

string

Published connector types for charging point slot 2.

  • AC Typ 2 Steckdose64%
  • DC Fahrzeugkupplung Typ Combo 2 (CCS)26%
  • AC Typ 2 Fahrzeugkupplung5%
  • Other (18)
Valid
84,110 · 72.2%
Missing
32,333 · 27.8%
Missing over timeMissing share of connector_types_2 over time, 0% to 100%.
Distinct
30 · 0% of valid

connector_power_kw_text_2

string

Published connector power values in kilowatts, retained as text because multiple connectors may be listed for charging point slot 2.

  • 2255%
  • 1114%
  • 3007%
  • Other (215)
Valid
84,110 · 72.2%
Missing
32,333 · 27.8%
Missing over timeMissing share of connector_power_kw_text_2 over time, 0% to 100%.
Distinct
227 · 0.3% of valid

evse_id_2

string

Published EVSE identifier for charging point slot 2.

  • DEBGL0%
  • DE BGL0%
  • DEBRP0%
  • Other (26,500)
Valid
26,893 · 23.1%
Missing
89,550 · 76.9%
Missing over timeMissing share of evse_id_2 over time, 0% to 100%.
Distinct
26,512 · 98.6% of valid

public_key_2

string

Published meter verification public key for charging point slot 2.

  • Wird nachgereicht1%
  • SAM0%
  • folgt nach Installation0%
  • Other (23,820)
Valid
24,581 · 21.1%
Missing
91,862 · 78.9%
Missing over timeMissing share of public_key_2 over time, 0% to 100%.
Distinct
23,832 · 97% of valid

connector_types_3

string

Published connector types for charging point slot 3.

  • AC Typ 2 Steckdose68%
  • DC Fahrzeugkupplung Typ Combo 2 (CCS)15%
  • AC Typ 2 Fahrzeugkupplung10%
  • Other (12)
Valid
5,348 · 4.6%
Missing
111,095 · 95.4%
Missing over timeMissing share of connector_types_3 over time, 0% to 100%.
Distinct
24 · 0.4% of valid

connector_power_kw_text_3

string

Published connector power values in kilowatts, retained as text because multiple connectors may be listed for charging point slot 3.

  • 2256%
  • 1121%
  • 6010%
  • Other (68)
Valid
5,348 · 4.6%
Missing
111,095 · 95.4%
Missing over timeMissing share of connector_power_kw_text_3 over time, 0% to 100%.
Distinct
80 · 1.5% of valid

evse_id_3

string

Published EVSE identifier for charging point slot 3.

  • DE SWI0%
  • DE*451*EBEACH01*030%
  • DE*811*E61234875*30%
  • Other (637)
Valid
659 · 0.6%
Missing
115,784 · 99.4%
Missing over timeMissing share of evse_id_3 over time, 99% to 100%.
Distinct
649 · 98.5% of valid

public_key_3

string

Published meter verification public key for charging point slot 3.

  • 3059301306072a8648ce3d020106082a8648ce3d03010703420004e383261cc282ead396c134b4528f04ce7c11a84df786459c0184564630f375812cc54b7b6aa8351c49a5307746e44507633ac26004c41c4e7cf4318e1712f2c41%
  • 3059301306072a8648ce3d020106082a8648ce3d0301070342000465e67f0240cfcfe97dd956062215363c64ac0f401dcd70614d732843ae2f60343b518b5ddc4907a5c1e425a290a44ff52b3c57728d01b41231585cb6eb2232980%
  • 3049301306072A8648CE3D020106082A8648CE3D030101033200040768276C0F9A90198F47795589816F9E80F078B6C60A5F5CCCC1F2AC0D9095417BEEFEDE3C1C14C76972D363AEF524970%
  • Other (1,326)
Valid
1,389 · 1.2%
Missing
115,054 · 98.8%
Missing over timeMissing share of public_key_3 over time, 0% to 100%.
Distinct
1,338 · 96.3% of valid

connector_types_4

string

Published connector types for charging point slot 4.

  • AC Typ 2 Steckdose75%
  • AC Typ 2 Fahrzeugkupplung14%
  • DC Fahrzeugkupplung Typ Combo 2 (CCS)5%
  • Other (1)
Valid
2,959 · 2.5%
Missing
113,484 · 97.5%
Missing over timeMissing share of connector_types_4 over time, 96% to 100%.
Distinct
13 · 0.4% of valid

connector_power_kw_text_4

string

Published connector power values in kilowatts, retained as text because multiple connectors may be listed for charging point slot 4.

  • 2253%
  • 1133%
  • 22; 224%
  • Other (38)
Valid
2,959 · 2.5%
Missing
113,484 · 97.5%
Missing over timeMissing share of connector_power_kw_text_4 over time, 96% to 100%.
Distinct
50 · 1.7% of valid

evse_id_4

string

Published EVSE identifier for charging point slot 4.

  • DE*811*E61234875*41%
  • DE*ELW*ELW0048*041%
  • DEKSLE0096041%
  • Other (354)
Valid
371 · 0.3%
Missing
116,072 · 99.7%
Missing over timeMissing share of evse_id_4 over time, 99% to 100%.
Distinct
366 · 98.7% of valid

public_key_4

string

Published meter verification public key for charging point slot 4.

  • 3059301306072a8648ce3d020106082a8648ce3d0301070342000465e67f0240cfcfe97dd956062215363c64ac0f401dcd70614d732843ae2f60343b518b5ddc4907a5c1e425a290a44ff52b3c57728d01b41231585cb6eb2232981%
  • 3059301306072a8648ce3d020106082a8648ce3d03010703420004e383261cc282ead396c134b4528f04ce7c11a84df786459c0184564630f375812cc54b7b6aa8351c49a5307746e44507633ac26004c41c4e7cf4318e1712f2c41%
  • 3049301306072A8648CE3D020106082A8648CE3D03010103320004629BA04E9A10C7214A80A42DFDDA496CEB45EBD353B5D08B093AF37A11D9F912182BCD2AA185F9931613F09009BBD0F71%
  • Other (696)
Valid
749 · 0.6%
Missing
115,694 · 99.4%
Missing over timeMissing share of public_key_4 over time, 99% to 100%.
Distinct
708 · 94.5% of valid

connector_types_5

string

Published connector types for charging point slot 5.

  • AC Typ 2 Steckdose68%
  • AC Typ 2 Fahrzeugkupplung24%
  • DC Fahrzeugkupplung Typ Combo 2 (CCS)6%
Valid
151 · 0.1%
Missing
116,292 · 99.9%
Missing over timeMissing share of connector_types_5 over time, 100% to 100%.
Distinct
6 · 4% of valid

connector_power_kw_text_5

string

Published connector power values in kilowatts, retained as text because multiple connectors may be listed for charging point slot 5.

  • 2268%
  • 1115%
  • 78%
Valid
151 · 0.1%
Missing
116,292 · 99.9%
Missing over timeMissing share of connector_power_kw_text_5 over time, 100% to 100%.
Distinct
11 · 7.3% of valid

evse_id_5

string

Published EVSE identifier for charging point slot 5.

  • DE*811*E61234875*52%
  • DE*ONE*EE3WU1%
  • DE*ISE*E01000321%
  • Other (91)
Valid
104 · 0.1%
Missing
116,339 · 99.9%
Missing over timeMissing share of evse_id_5 over time, 100% to 100%.
Distinct
103 · 99% of valid

public_key_5

string

Published meter verification public key for charging point slot 5.

  • 0599 34A3 F3F8 9B3C 5388 E1F9 4474 1A5E 3BDC 1EF5 5E5B 6D32 B39A E46E 5475 A493 EAB4 7FD6 0E34 33E0 D5A2 083C DFD9 B5B42%
  • 0F0D 5D88 2E20 4AC1 E8C7 BECE 593B B99A 7CA0 A355 74AF CD7C E90B DFFE 0E19 831B 1E32 1CA3 EE37 62C2 7A7D DDB5 3E25 AA132%
  • 199B 5C95 E4E2 11DF 08EE 8453 2E66 40E7 1E2C 20C1 76C5 4C9A 2B25 82FE 1566 57FE 59F5 60CE 65A6 D625 C29E 1370 D516 C7D32%
  • Other (50)
Valid
62 · 0.1%
Missing
116,381 · 99.9%
Missing over timeMissing share of public_key_5 over time, 100% to 100%.
Distinct
62 · 100% of valid

connector_types_6

string

Published connector types for charging point slot 6.

  • AC Typ 2 Steckdose62%
  • AC Typ 2 Fahrzeugkupplung29%
  • DC Fahrzeugkupplung Typ Combo 2 (CCS)7%
Valid
125 · 0.1%
Missing
116,318 · 99.9%
Missing over timeMissing share of connector_types_6 over time, 100% to 100%.
Distinct
4 · 3.2% of valid

connector_power_kw_text_6

string

Published connector power values in kilowatts, retained as text because multiple connectors may be listed for charging point slot 6.

  • 2265%
  • 1116%
  • 710%
Valid
125 · 0.1%
Missing
116,318 · 99.9%
Missing over timeMissing share of connector_power_kw_text_6 over time, 100% to 100%.
Distinct
12 · 9.6% of valid

evse_id_6

string

Published EVSE identifier for charging point slot 6.

  • DE*811*E61234875*62%
  • DE*ISE*E01000331%
  • 085413901%
  • Other (68)
Valid
81 · 0.1%
Missing
116,362 · 99.9%
Missing over timeMissing share of evse_id_6 over time, 100% to 100%.
Distinct
80 · 98.8% of valid

public_key_6

string

Published meter verification public key for charging point slot 6.

  • 18D7 7FE5 3B39 F4F7 C813 DE3F 335B 2D1A 16AA 3D8B 3F9A 5D43 9BFB 4A71 D8EB 8CFA E5DB 37F0 83A1 6668 F474 23F3 E124 0E1C2%
  • 1C81 4299 0942 0550 6BEA 9E1E 3BA1 DF8E 46C1 E634 7AE8 A0B6 2CB9 9298 97A6 CC22 EE69 E1B0 0391 18C6 02D5 330C 1856 28EB2%
  • 3059 3013 0607 2A86 48CE 3D02 0106 082A 8648 CE3D 0301 0703 4200 04E7 C96D F433 CCC7 19D7 79C3 4B27 80D3 62BA C876 00BB CAE5 07D2 524C 3B76 7CB0 CE9D CEBE 8FEB 8F0D 58DB 3683 FA26 0EC0 900F 73E6 47F4 3713 3855 8CCE 0422 545C 6B2%
  • Other (33)
Valid
45 · 0%
Missing
116,398 · 100%
Missing over timeMissing share of public_key_6 over time, 100% to 100%.
Distinct
45 · 100% of valid

registry_as_of

date

Snapshot date stated in the CSV publisher preamble.

  • 2026-09-01100%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
1 · 0% of valid

operator_name_key

string

Lowercased trimmed operator label for searching; this is not a resolved company identity.

  • enbw mobility+ ag und co.kg5%
  • tesla germany gmbh3%
  • e.on drive germany gmbh3%
  • Other (11,731)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
11,743 · 10.1% of valid

operator_sector_clef

string

Clef sector label inferred only from the published operator name; unknown means insufficient evidence.

  • charging_specialist27%
  • energy_company25%
  • unknown14%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
10 · 0% of valid

operator_sector_probability

decimal

Model probability assigned to its selected operator sector; not independently calibrated.

  • 0.6206000005%
  • 0.8445000003%
  • 0.7173000003%
  • Other (5,048)
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
5,060 · 4.3% of valid
Min
0.200500000
25%
0.500700000
Median
0.675400000
75%
0.844500000
Max
0.946900000

operator_sector_model

string

Exact served CLEF model pin recorded by the classification service.

  • cloudflare/clef-flash-fp8-17f0b0ad100%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
1 · 0% of valid

is_open_24_7

boolean

True for published opening hours code 247, false for Eingeschränkt, otherwise null.

  • true95%
  • false5%
Valid
42,229 · 36.3%
Missing
74,214 · 63.7%
Missing over timeMissing share of is_open_24_7 over time, 0% to 100%.
Distinct
2 · 0% of valid

has_ccs_connector

boolean

Whether any published charging point slot explicitly lists a CCS connector.

  • false72%
  • true28%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2 · 0% of valid

has_chademo_connector

boolean

Whether any published charging point slot explicitly lists a CHAdeMO connector.

  • false97%
  • true3%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2 · 0% of valid

has_type2_connector

boolean

Whether any published charging point slot explicitly lists a Type 2 connector.

  • true77%
  • false23%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2 · 0% of valid

coordinate_review_needed

boolean

Whether published coordinates lie outside broad Germany bounds of latitude 47 to 56 and longitude 5 to 16; review flag, not a verified error.

  • false100%
  • true0%
Valid
116,443 · 100%
Missing
0 · 0%
Distinct
2 · 0% of valid

Table profile

Profile of the served version, all rows, computed 16 Nov 2026, 18:12 UTC

PassedFreshnessLatest event 68 d before this version
WarningGaps9 empty years, 1993 to 1999, 2002 and 2006
WarningAnomaliesGap on 2002, 0 rows against about 1, and 2 more
PassedUnique keysEvery facility_id is unique
Rows per year
Rows per year, 35 buckets from 1 Jan 1992 to 1 Jan 2026, at most 23,797 rows, 9 empty, 3 marked as anomalies.30k1 Jan 1992: 1 row1 Jan 1993: 0 rows1 Jan 1994: 0 rows1 Jan 1995: 0 rows1 Jan 1996: 0 rows1 Jan 1997: 0 rows1 Jan 1998: 0 rows1 Jan 1999: 0 rows1 Jan 2000: 1 row1 Jan 2001: 2 rows1 Jan 2002: 0 rows, gap, about 1 expected1 Jan 2003: 1 row1 Jan 2004: 8 rows, spike, about 2 expected1 Jan 2005: 1 row1 Jan 2006: 0 rows, gap, about 3 expected1 Jan 2007: 4 rows1 Jan 2008: 1 row1 Jan 2009: 3 rows1 Jan 2010: 33 rows1 Jan 2011: 93 rows1 Jan 2012: 131 rows1 Jan 2013: 101 rows1 Jan 2014: 171 rows1 Jan 2015: 388 rows1 Jan 2016: 883 rows1 Jan 2017: 1,602 rows1 Jan 2018: 3,544 rows1 Jan 2019: 4,930 rows1 Jan 2020: 6,469 rows1 Jan 2021: 9,681 rows1 Jan 2022: 15,349 rows1 Jan 2023: 23,797 rows1 Jan 2024: 19,773 rows1 Jan 2025: 19,897 rows1 Jan 2026: 9,579 rows1995200020052010201520202025

Support

Talk to Mostly Right

Loading chat…