Description
Hourly electricity demand, generation mix and predicted demand for 60 US grid operators since 2015, scored against the operators' own day-ahead forecasts.
Accuracy: 12-week out-of-sample backtest
Each week from 24 August to 15 November 2026 was predicted using only data from before that week. Error is demand-weighted: the sum of |forecast - actual| over the sum of actual demand. It counts only hours with demand above zero, every forecast present, and both errors under 100%.
| Scope | TabICLv2 | Operator forecast | Bias-corrected baseline |
|---|---|---|---|
| All 52 operators | 2.66% | 4.40% | 2.83% |
| 7 ISOs | 1.95% | 3.15% | 2.16% |
| 42 operators with clean forecasts | 2.23% | 2.75% | 2.22% |
- Operator forecasts are as EIA-930 publishes them, with PJM shifted one hour to line it up.
- The baseline multiplies each operator forecast by its own 28-day ratio of demand to forecast, for each hour of the day.
- Much of the gain over operators comes from operator forecasts with a fixed bias. On clean forecasts, the model ties the baseline.
- The model wins every one of the 12 weeks against operators. It beats the baseline in 10 of 12.
- Band coverage: the 10th to 90th percentile band held 66% of actual hours, not the 80% target. The band is too narrow.
Tables: us_grid_backtest_scoreboard scores each scope and operator overall and week by week. us_grid_backtest_vs_baseline holds every backtest hour with flags and the baseline.
Live accuracy
us_grid_prediction_accuracy scores each live prediction once EIA publishes the actual. It is rebuilt every 6 hours. From 20 to 24 November 2026, 7,274 hours across 52 operators scored 3.88% against 6.34% for the operators' published forecasts, and the band held 63%. EIA publishes one to two days late, so most live predictions fill hours that have already happened, using recent weather. Read them as gap-filling accuracy, not day-ahead skill. us_grid_prediction_log keeps every live prediction as it was first made.
Getting the predictions
- No account needed: the first 500 rows of each table, the schema and a preview, from
GET https://mostlyright.md/api/v2/public/tables/{tableId}/preview. Live accuracy: https://mostlyright.md/api/v2/public/tables/80bbc630-6981-4bca-839e-219010c7bdb1/preview. Scoreboard: https://mostlyright.md/api/v2/public/tables/14d64b49-fd7c-4673-99fe-4243483a3dde/preview. The same reads work over MCP at https://mostlyright.md/api/mcp. - With a free account key:
POST /api/v2/public/tables/{tableId}/queryfor filtered reads, orGET .../currentfor the full Parquet file. - To run the same TabICLv2 model on your own data, build a dataset with a free account and use the
predictmodel in a recipe. There is no anonymous prediction API.
Coverage
- Window: 1 July 2015 to the newest hour EIA has published, in UTC.
- 60 balancing authorities in 13 EIA regions. 52 have a day-ahead forecast, so they have predictions.
- Rebuilt daily after EIA's update. Unpublished hours are predicted up to 120 hours past each operator's newest published hour.
Missing values
Fuel columns start in July 2018, battery and pumped storage in July 2024, temperature in 2026. Hours without a positive operator forecast get no prediction.
Source and rights
U.S. Energy Information Administration, Hourly Electric Grid Monitor (EIA-930), public domain. Cite EIA. Temperature is from Open-Meteo, CC BY 4.0. TabICLv2 is BSD 3-Clause. Predictions are rerun on each rebuild, so us_grid_prediction_log keeps the originals.
Tables5
Grid data and predictions
2
- Table healthStatus unavailableHourly grid dataTable overviewPublished rows6,347,093Columns27 rows1 Jul 2015 to 25 Nov 2026 · latest event 10 h before refreshStatus unavailable1 Jul 2015 to 25 Nov 2026 · latest event 10 h before refresh
- Table healthStatus unavailablePrediction logTable overviewPublished rows8,604Columns11 rows20 Nov 2026 to 26 Nov 2026 · latest event 12 h before refreshStatus unavailable20 Nov 2026 to 26 Nov 2026 · latest event 12 h before refresh
Accuracy
3
- Table healthStatus unavailableAccuracy scoreboardTable overviewPublished rows727Columns11 rowsStatus unavailable
- Table healthStatus unavailableLive accuracyTable overviewPublished rows8,604Columns17 rows17 Nov 2026 to 25 Nov 2026 · latest event 2 d before refresh · 7 anomaliesStatus unavailable17 Nov 2026 to 25 Nov 2026 · latest event 2 d before refresh · 7 anomalies
- Table healthStatus unavailableBacktest hoursTable overviewPublished rows102,766Columns26 rows24 Aug 2026 to 15 Nov 2026 · latest event 11 d before refresh · 2 anomaliesStatus unavailable24 Aug 2026 to 15 Nov 2026 · latest event 11 d before refresh · 2 anomalies
Details
- Contents
- 5 tables · 6,467,794 rows · 92 columns
- Category
- Energy
- Updated
- Published
- Version
- 2026-11-27
- License
- CC BY 4.0 — attribution
- Visibility
- Public
- Publisher
- Mostly Right
- Topics
- electricity · power grid · demand +4
Activity
Discover
Mostly Right·26 Nov 2026, 13:56:50 UTCUS Grid Day-Ahead Demand Forecast Accuracy Scorecard
- 103.5K rows (estimated)103.5K
- 131 views131
- 0 uses. Uses include downloads and successful API/MCP queries0

Mostly Right·25 Nov 2026, 12:25:39 UTCAlaska air quality PM2.5 and PM10 with temperature
- 168.1K rows (estimated)168.1K
- 101 views101
- 0 uses. Uses include downloads and successful API/MCP queries0

Mostly Right·25 Nov 2026, 12:21:02 UTCEl Salvador municipality and city population, 1975-2030
- 1.4K rows (estimated)1.4K
- 135 views135
- 0 uses. Uses include downloads and successful API/MCP queries0